AFB013 Anti-Intrusion Alarm By Bus Didactic Bench Educational Equipment Vocational Training Refrigeration Laboratory Equipment
Metal Structure mobile on wheels
Power Supplies protected by a differential circuit breaker, with emergency stop.
The power supply control circuit must be in SELV
The dynamometer consists at a minimum of the following components:
A central BUS to2 monitored areas at minimum:
With display of the history of events
With integrated keyboard for implementation monitoring off
10 Different codes minimum: master code, code installer ,6codes users minimum
A radio keyboard info command equipped with a LCD display:
Viewing the status of the system
Command the outside monitoring
Two infrared detectors minimum scope 10m (90 degrees)
Two detectors volumetric bis infrared and microwave. Minimum Scope 10m (90 degrees).
Contact Interface bus allows the connection of any type of sensor with a contact to opening on the network BUS (8 entries minimum)
An optical smoke detector
A siren at 4 different tones (intrusion-fire-technical-distress)
Fed by the BUS
Two opening contact intended for the protection of openings (doors, windows..)
NB: All components must be compatible between them
The bench must allow the minimum:
The programming of the central with several type of entries or by zone.
The connection of the sensors to the central
NB: All terminals must be postponed on safety bushings.
The alarm panel we comes from by voice message on a laptop in the event of intrusion attempt
To enable or disable the system
To define several scenarios by combining of detectors at the central
Capture the intrusion attempts and activate the siren
The bench must be supplied with all necessary accessories for connecting el the commissioning of the didactic system
Electrician tools